This roof assembly seems quite cathedral however, if i have an understanding of effectively its not vented whatsoever, but has generous above sheathing foam. Is that this considered a vapour Protected assembly thinking of this short article states "Install rigid foam insulation earlier mentioned the roof sheathing and air-permeable insulation concerning the rafters.

"R-19 batts are very air permeable, and on long unobstructed rafter bays you may have pretty a stack influence. It doesn't take a massive level of air leakage to offer some drying there. Also, When the batts are unfaced or kraft-confronted, the drying toward the interior might be significant.

If you would like make an unvented insulated roof assembly, you almost certainly don't need to disturb the tile roofing. That implies that essentially the most appropriate insulation might be spray polyurethane foam. Certainly, the prevailing insulation should be eliminated before you put in the spray foam.

You seem uncertain. By way of example, you wrote, "it's not vented whatsoever." But in my article -- the report on this page, in which you posted your comment -- I wrote, "you can find 3 ways to build an unvented roof assembly." I then proceeded to elucidate how to make this type of roof. I stated that it is feasible

Lots of my neighbors below have cathedral ceilings, no attics and Unquestionably no insulation (mainly they've aluzinc roofs on plywood with pine rafters).

Doug I agree, a lot of wrongs "overthinking" and overdoing. I as soon as had to resupply a health care provider setting up an aircraft with dozens of AN plane bolts as they were being tightened to the point of breaking the bolts. Fewer is a lot more from time to time... Along with the KISS rule.

The particular design demonstrated was to get a Passive Home. The roof thickness & utilization of a provider cavity could look like overkill for most initiatives, but If you prefer an airtight lid, a company cavity can get you there - completely... And permit you to Recommended Site wire and light-weight the interior.

Like most mansard roofs, your roof is unvented. Your mansard roof has distinct sections -- the steep sections for the perimeter, along with the low-slope segment in the middle. All of these sections should be insulated in an identical way, due to the fact all these roof assemblies are unvented.

My emotion is that the dew level profile would find yourself from the XPS foam board, as a result a VB ought to be placed on initial deck. To be able of assembly:

two. When you install fiberglass batts, air barriers are way more important than vapor Manage. You will need a fantastic air barrier on either side of the fiberglass batts.

Of course, it's Risk-free (although before you question an issue about a specific roof assembly, It could be good to know your local weather zone).

Getting spent all my existence driving a desk focusing roofing company business cards on it is a little bit of a split. The roof is going to be performed in Probably four sections so might test rigid foam and spray foam to compare what operates. Rigid foam is wearisome but negligible sticky residue. Many thanks.

Most rafters aren’t More Help deep enough to support the insulation necessary to meet minimum amount R-values demanded by code, particularly if the rafter bays include things like a ventilation channel.

If you decide on to setup open-mobile spray foam instead of closed-mobile spray foam, your roof assembly might be able to dry somewhat to the interior. Just be sure that the spray foam layer is thick enough to keep your rafter bays higher than the dew position throughout the winter.