Q. "I'm thinking if I must furr out the rafters to obtain the specified thickness of spray foam, or if installing several inches of polyiso foam for the underside of your rafters, once the spray foam, could work?"

The main vent baffles to strike the industry — the basic Right-Vent from the 1970s and ’80s — were being cheap, flimsy things product of skinny polystyrene. Polystyrene baffles have several disadvantages: becoming slim and flexible, they're able to’t resist the pressures from dense-packed cellulose or blown-in fiberglass; they don’t ventilate the complete width in the rafter bay; and as generally installed, they permit air to leak out the highest of the insulated assembly.

I'm coming up with a residence and we have been using cellulose in 2x12 roof rafters, and I came upon an item that looked excellent. It really is an insulated nailbase termed Interesting-Vent by Hunter Panels. It offers up to 25.6 R-value in foam insulation (in thicknesses nearly six" which include a one" airspace and plywood) though supplying a cooling vent underneath the shingles, and easy installation for that roofing with the nailbase.

I've developed log homes while in the Yukon Territory in northern Canada for thirty decades. Most log structures have cathedral ceilings. Many of the roofs We now have created are as follows (from the bottom up): log purloins, nominal two" (2x6) t&g decking, 6mil poly, one 1/2" extruded polystyrene foam, 2x10 rafters on 24" facilities, 7" fiberglass, 2x4 strapping, 7/sixteen OSB, underlayment (15 lb paper, 30lb felt, or now we might even use ice and h2o defend). There could well be about an inch of air Place below the strapping for both vertical and horizontal air move. All roofs are vented with strip vents for the eaves and vents in the soffit (2x6 t&g) at the peak at both equally finishes. I would disagree that venting will not be necessary should you quit the airflow on The nice and cozy aspect, for two explanations. To start with it is very difficult to halt all airflow, Primarily with standard common techniques about his (ie chimney and plumbing vent penetrations with the roof) We have many procedures produced over the years to seal the vb at the eaves and gables, but there are still nail penetrations in the vb. In general I believe we had really tight seals but one particular could by no means say airtight.

I'm unsure should you are interested in the making science remedy or a code response. From the code viewpoint, this is a roof that has to be insulated to R-forty nine.

Doug I concur, too many wrongs "overthinking" and overdoing. I when needed to resupply a doctor setting up an aircraft with dozens of the aircraft bolts mainly because they have been tightened to the point of breaking the bolts. Significantly less is much more sometimes... Along with the KISS rule.

You're proposing a vented roof assembly. For the vented roof assembly, the code will not demand that any foam insulation be put in direct Make contact with with your roof sheathing -- on the contrary.

That seems to be incredibly appealing: go with R-thirty about the underside on the deck at our home using a combination of fiberglass batts and XPS as I described previously mentioned, then add an extra R-10 (2" XPS) on the very best side when we tear down and re-roof? Unfortunately that appears like It truly is far too quick.

Most business roof assemblies Will not hassle with the fluffy stuff. They simply fulfill a hundred% from the R-worth needs for the roof with rigid foam (possibly EPS or polyiso) and skip the batts totally. That's just how I recommend that you commence.

As The pinnacle of our area HBA, I've strenuously identified that foam in excess of a vented flat roof assembly doesn't supply the visit this web-site insulation values promised. Some builders have recommended they may simply seal and stucco more than the stucco vents and eliminate the air flow.

Of course, it is Secure (While prior to deciding to ask a matter about a selected roof assembly, It might be excellent to understand your local climate zone).

Amish creating crews are rather confined by their geography, but will vacation as much as various hrs and in many cases over and above to finish a job (from time to time involving overnight stays). Verify the guideline beneath for an Amish builder near you.Advertisement

Ventilation channels are made by installing a fabric that can sustain a separation (an air gap) in between the insulation along with the roof sheathing.

In the absence of an airtight ceiling, roof air flow can do a lot more harm than great, due to the fact air movement in rafter bays can encourage indoor air Full Report to leak by way of ceiling cracks.