With regards to set up: When it's been effectively mounted in Europe for many years, we've just gotten the material, and so we stay up for having it on the career web site shortly and actually installing it - not to mention, reporting back again how it went.

I such as element supplied but I would not connect with that a cathedral ceiling affliction because it consists of ceiling joists spanning at The underside from the roof rafters. I might connect with this an insulated attic.

More details on how to insulate an unvented roof assembly is offered from the post on this website page.

If you want to do it right, you might want to deal with air leaks, deal with your recessed can problem, and add adequate R-worth to at least satisfy minimum code requirements. It can be lots of perform, but it is not rocket science. Fixing these challenges could be expensive, nevertheless.

The very best strategy is to perform the many function without delay: rigid foam above the roof sheathing (as suggested in the short article), and fluffy insulation underneath.

This can be a choice I'm thinking of in my property to save lots of the previous owners recently installed roof shingles, but the depth of your rafters are unable to accomodate ample insulation to fulfill code. I'm asking yourself if I should really furr out the rafters to get the specified thickness of spray foam, or if setting up several inches of polyiso foam to the underside on the rafters, after the spray foam, could get the job done?

That you are proposing a vented roof assembly. For a vented roof assembly, the code does not involve that any foam insulation be put in immediate Call with your roof sheathing -- Quite the opposite.

Like most mansard roofs, your roof is unvented. Your mansard roof has distinct sections -- the steep sections within the perimeter, as well as reduced-slope area in the center. Every one of these sections must be insulated in an identical way, since every one of useful site these roof assemblies are unvented.

If you'd like to put in a combination of rigid foam on top of your roof sheathing and air-permeable insulation between your rafters, you have to ensure that your rigid foam is thick enough to keep your roof sheathing over the dew place.

So as to add counties from a number of states: 1st select a condition from fall-down then select its counties. then only pick out the subsequent state within the fall-down . ALL chosen counties from all states will display in the 'selected counties' box. (Keep CTRL to pick numerous click here for info counties)

Your assembly requires about five inches of XPS, for a total R-worth of only R-25. That's not Considerably. In case you will all that difficulties to make a sophisticated roof assembly, it is best to goal higher.

I see the recommendation is that when starting with board sheathing, 1 ought to put a watertight membrane about the sheathing prior to installing the lowest layer of foam. Nevertheless, in my situation the roofer has previously accomplished inserting new felt around the T&G board ceiling/roof deck. Can that felt substitute for over at this website the prescribed watertight membrane, below in San Jose/Climate Zone three?

The high density fiberglass is so far more dense in comparison to the medium and small density fiberglass that it looks as if it should reduce the likely for convection within the batts, but at two to 3 occasions the cost of medium density fiberglass batts the attain could possibly be nominal and not worth the included cost. Many thanks for sharing your experience,

Sorry, Martin, I now realize that "new building" will not necessarily mean "new home being crafted", and "an unvented attic, with R-fifty beneath the roof" should have been "an unvented attic, with an R-50 roof'. Just because It is obvious to me doesn't suggest It really is very clear to Absolutely everyone else.